All CJC-1295 (No DAC) + Ipamorelin certificates

CJC-1295 (No DAC) + Ipamorelin 10 mg Certificate of Analysis Batch APL-CJCIP10-2608-03

CJC-1295 (No DAC) + Ipamorelin 10 mg from batch APL-CJCIP10-2608-03 was analysed on 15 August 2026 and measured 99.08% combined purity across Ipamorelin and CJC-1295 (No DAC) by HPLC / Mass Spectrometry, passing all 5 release tests.

Combined purity
99.08%
Components
Ipamorelin, CJC-1295 (No DAC)
Result
All 5 tests passed
Tested
15 August 2026
Method
HPLC / Mass Spectrometry
Net content
10.07 mg

Independent verification

CJC-1295 (No DAC) + Ipamorelin 10 mg is independently verified by Ozcanium Analytics, an independent Australian laboratory, at 99.16% purity by UPLC-MS/MS, analysed 27 August 2026 on lot APL-CJCIP10-2608-01, net content Ipamorelin 5.10 mg, CJC-1295 (No DAC) 5.29 mg, verification code OZ-HPLCMS-JKJ2; bacterial endotoxin below 15.0 EU per vial by kinetic chromogenic LAL, analysed 28 August 2026, verification code OZ-ENDOTX-TPA1.

Issued by Ozcanium Analytics. Covers every vial size of this compound; each report opens as the laboratory issued it.

Enter a code in the Ozcanium Analytics verification portal (opens in a new tab) to confirm the report against their own records.

The certificate as issued is reproduced below — pinch to zoom on a phone, or use Print / Save as PDF for a full-size copy.

Australian Peptide Labs

In-House Analytical Laboratory

Australian Peptide Labs Pty Ltd

ABN 55 696 074 361

australianpeptidelabs.com.au

Page 1 of 3

Certificate of Analysis CJC-1295 (No DAC) + Ipamorelin 10 mg Batch APL-CJCIP10-2608-03
Compound Mix
CJC-1295 (No DAC) + Ipamorelin
Lot Number
APL-CJCIP10-2608-03
Analysis Date
15 August 2026
Method
HPLC / Mass Spectrometry
Purity
99.08%
Net Content
10.07 mg
CJC-1295 (No DAC) + Ipamorelin vial
Net Content
  • Ipamorelin5.04 mg
  • CJC-1295 (No DAC)5.03 mg
Form
Lyophilised Powder
Manufactured
August 2026
Issued
16 August 2026
Document ID
APL-COA-CJCIP10-2608-03
Verification Code
Batch traceable

High Performance Liquid Chromatography (HPLC-UV) Chromatogram

mAUPDA 214 nm018837556375033.544.555.566.5 min 3.580Ipamorelin3.6404.080CJC-1295 (No DAC)4.3104.6505.870

Components resolved at 3.58 min (Ipamorelin, 39.95%), 4.08 min (CJC-1295 (No DAC), 59.13%); combined peptide area 99.08%. No single impurity peak exceeds 0.36%.

Peak List

#Time (min)Area% AreaAssignment
13.5802,876,61639.950Ipamorelin
23.64017,2800.240—
34.0804,257,14459.130CJC-1295 (No DAC)
44.31025,9200.360—
54.65014,4000.200—
65.8708,6400.120—

Analytical Results

TestSpecificationResultStatus
AppearanceWhite/Off-White Lyophilised PowderConformsPASS
Identity (MS)All components confirmedConfirmedPASS
Purity (HPLC)≥98.0% combined99.08%PASS
Total Peptide Content95–105%99.0%PASS
Endotoxins<0.5 EU/mg<0.25 EU/mgPASS

Australian Peptide Labs

In-House Analytical Laboratory

Australian Peptide Labs Pty Ltd

ABN 55 696 074 361

australianpeptidelabs.com.au

Page 2 of 3

Ipamorelin

PubChem CID: 9831659 · CAS Number: 170851-70-4

Formula: C38H49N9O5 · MW: 711.85 g/mol · In this vial: 5.04 mg

SequenceAib-His-D-2-Nal-D-Phe-Lys-NH2

Liquid Chromatography Mass Spectrometry (LC-MS) Identity Analysis

Identity confirmation with SIM

Monitored (m/z)Detected (m/z)Relative Intensity
357356.93.47
713712.862.4

Detection assignment: Ipamorelin

Collected Mass Spectrum

Intensity ×107

0123401002003004005006007008009001000 m/z 357713

Australian Peptide Labs

In-House Analytical Laboratory

Australian Peptide Labs Pty Ltd

ABN 55 696 074 361

australianpeptidelabs.com.au

Page 3 of 3

CJC-1295 (No DAC)

PubChem CID: 91971820 · CAS Number: 446262-90-4

Formula: C152H252N44O42 · MW: 3367 g/mol · In this vial: 5.03 mg

SequenceTyr-D-Ala-Asp-Ala-Ile-Phe-Thr-Gln-Ser-Tyr-Arg-Lys-Val-Leu-Ala-Gln-Leu-Ser-Ala-Arg-Lys-Leu-Leu-Gln-Asp-Ile-Leu-Ser-Arg-NH2

Liquid Chromatography Mass Spectrometry (LC-MS) Identity Analysis

Identity confirmation with SIM

Monitored (m/z)Detected (m/z)Relative Intensity
674674.421.18
843842.761.3
11231123.342.1

Detection assignment: CJC-1295 (No DAC)

Collected Mass Spectrum

Intensity ×107

00.511.522.5300500700900110013001500 m/z 6748431123

Verification Protocol

  • Identity confirmed separately for each component by mass spectrometry against its own expected ion channels.
  • Purity measured by HPLC as the combined area of every assigned component peak against all integrated impurity peaks.
  • Batch traceability: this document reports the lot number printed on the vial.
  • Analysis performed in-house by Australian Peptide Labs.

Supplied for laboratory research use only. Not a therapeutic good; not for human or veterinary use.