All certificates

Certificate library

TB-500 Certificate of Analysis

Ozcanium
98.00%
Independent · 27 Aug 2026
Current batch
98.67%
APL-TB10-2608-03
Batches published
3
Measured purity
98.67% – 99.21%
Most recent analysis
19 August 2026

Independent verification

TB-500 is independently verified by Ozcanium Analytics, an independent Australian laboratory, at 98.00% purity by UPLC-MS/MS, analysed 27 August 2026 on lot APL-TB10-2608-01, net content 9.73 mg, verification code OZ-HPLCMS-MJ39.

Issued by Ozcanium Analytics. Covers every vial size of this compound; each report opens as the laboratory issued it.

Enter a code in the Ozcanium Analytics verification portal (opens in a new tab) to confirm the report against their own records.

TB-500 is independently verified by Ozcanium Analytics at 98.00% purity by UPLC-MS/MS, analysed 27 August 2026. Every batch of TB-500 is also assayed in our own laboratory before it is released. Purity is measured by HPLC / Mass Spectrometry on the PDA 214 nm channel, reported as main-peak area against every integrated impurity peak. Molecular identity is confirmed by LC-MS across 3 monitored ion channels. The release specification is ≥98.0%. Across the 3 batches published here, measured purity spans 98.67% – 99.21%.

Current batch — APL-TB10-2608-03

View the full certificate
Document ID
APL-COA-TB10-2608-03
Net content
10.14 mg
Tested
19 August 2026
Method
HPLC / Mass Spectrometry
TestSpecificationResultStatus
AppearanceWhite/Off-White Lyophilised PowderConformsPASS
Identity (MS)ConfirmedConfirmedPASS
Purity (HPLC)≥98.0%98.67%PASS
Peptide Content95–105%98.2%PASS
Endotoxins<0.5 EU/mg<0.15 EU/mgPASS
mAUPDA 214 nm0250500750100022.533.544.555.5 min 2.5102.7702.950TB-5003.5204.770
Main peak integrated at 98.67% of total area; no single impurity peak exceeds 0.52%.
Peak list — 5 detected
#Time (min)Area% AreaIdentification
12.51027,3600.380—
22.77037,4400.520—
32.9507,104,24098.670TB-500
43.52019,4400.270—
54.77011,5200.160—
Identity confirmation with SIM
Monitored (m/z)Detected (m/z)Intensity
828828.241.3
994993.692.8
12421241.861.6

TB-500

Intensity ×107

0123500700900110013001500 m/z 8289941242

Every published TB-500 batch

Match the batch number printed on your vial to open its certificate.

BatchSizeTestedPurityCertificate
APL-TB10-2608-0310 mg19 August 202698.67% View
APL-TB10-2607-0210 mg22 July 202699.21% View
APL-TB10-2606-0110 mg22 June 202698.93% View

Earlier batches in full

APL-TB10-2607-0299.21% purity tested 22 July 2026
Document ID
APL-COA-TB10-2607-02
Net content
10.10 mg
Tested
22 July 2026
Method
HPLC / Mass Spectrometry
TestSpecificationResultStatus
AppearanceWhite/Off-White Lyophilised PowderConformsPASS
Identity (MS)ConfirmedConfirmedPASS
Purity (HPLC)≥98.0%99.21%PASS
Peptide Content95–105%98.6%PASS
Endotoxins<0.5 EU/mg<0.25 EU/mgPASS
Peak list — 5 detected
#Time (min)Area% AreaIdentification
12.51911,7950.160—
22.78827,4710.380—
32.9697,204,33799.210TB-500
43.53511,3060.160—
54.7796,3460.090—
Identity confirmation with SIM
Monitored (m/z)Detected (m/z)Intensity
828828.261.23
994993.71.86
12421241.861.66

TB-500

Open the APL-TB10-2607-02 certificate for its chromatogram and spectrum
APL-TB10-2606-0198.93% purity tested 22 June 2026
Document ID
APL-COA-TB10-2606-01
Net content
10.11 mg
Tested
22 June 2026
Method
HPLC / Mass Spectrometry
TestSpecificationResultStatus
AppearanceWhite/Off-White Lyophilised PowderConformsPASS
Identity (MS)ConfirmedConfirmedPASS
Purity (HPLC)≥98.0%98.93%PASS
Peptide Content95–105%99.5%PASS
Endotoxins<0.5 EU/mg<0.20 EU/mgPASS
Peak list — 5 detected
#Time (min)Area% AreaIdentification
12.48826,2970.410—
22.73520,9790.320—
32.9106,409,23098.930TB-500
43.47811,0550.170—
54.72610,7390.170—
Identity confirmation with SIM
Monitored (m/z)Detected (m/z)Intensity
828828.231.18
994993.662.88
12421241.881.8

TB-500

Open the APL-TB10-2606-01 certificate for its chromatogram and spectrum

TB-500 testing — common questions

Is TB-500 third-party tested?
Yes. TB-500 is independently verified by Ozcanium Analytics, an independent Australian laboratory, at 98.00% purity by UPLC-MS/MS, analysed 27 August 2026 on lot APL-TB10-2608-01, net content 9.73 mg, verification code OZ-HPLCMS-MJ39. The report is published on this page as the laboratory issued it, and each verification code can be redeemed in the lab's own portal so the document is confirmed against their records rather than ours. Every batch of TB-500 is also analysed in our own laboratory and published here in full.
What purity is the current batch of TB-500?
Ozcanium Analytics, an independent Australian laboratory, measured TB-500 at 98.00% by UPLC-MS/MS on 27 August 2026. In our own laboratory, batch APL-TB10-2608-03, the batch currently shipping, measured 98.67% by HPLC / Mass Spectrometry, tested 19 August 2026. The release specification is ≥98.0%. Across the 3 batches published here, measured purity spans 98.67% – 99.21%.
How do I find the certificate for the TB-500 vial I have?
Each certificate reports one production batch, so match the batch number printed on your vial against the batch history on this page rather than against the compound in general. 3 batches are published: APL-TB10-2608-03, APL-TB10-2607-02 and APL-TB10-2606-01. If the batch you hold isn't listed, email [email protected] with the compound and batch number and we'll send the document.
What is TB-500 tested for?
Every batch is tested for Appearance, Identity (MS), Purity (HPLC), Peptide Content and Endotoxins. Each result is printed beside a fixed specification — ≥98.0% for purity, set as house policy rather than per batch, so a batch cannot pass by having its target moved. Molecular identity is confirmed by LC-MS across 3 monitored ion channels.

TB-500 identification

The registry identifiers printed on every TB-500 certificate. They are what lets the compound be checked against a public record independently of anything we assert about it.

CAS Number
77591-33-4
Molecular Formula
C212H350N56O78S
Molecular Weight
4963.4 g/mol
Form
Lyophilised Powder
Presentation
10 mg

Sequence

Ac-SDKPDMAEIEKFDKSKLKKTETQEKNPLPSKETIEQEKQAGES (43 aa, N-terminally acetylated)

Next

Holding a TB-500 batch that isn't listed above? Email [email protected] with the batch number and we'll send the document. For the analytical method behind these figures, see our guide to HPLC in peptide quality control.

All products are supplied for laboratory research use only. They are not therapeutic goods and are not for human or veterinary use.